49909390

3.2.1. Adjustment check

Fig. 3.2. Adjustment of the drive of coupling: 1 – adjusting nut; 2 – lock-nut; 3 – cable cover stopper; 4 – coupling switching off fork


Measure by a caliper distance between a stopper of a cover of a cable and the end of a fork of switching off of coupling (see fig. 3.2):
– at a starting position of a pedal of coupling;
– at the pedal of coupling pressed against the stop.

Fig. 3.3. Coupling switching off fork course


The course of a fork of switching off of coupling has to be equal: (x) =29,5 mm ±0,5 mm (fig. 3.3).