49909390

2.2.10.5. Check of axial movement of camshafts

Install camshafts, having provided correctness of their situation, and a cover of a head of the block of cylinders.

Fig. 2.116. Order of tightening of bolts of fastening of a cover and head of the block of cylinders


Tighten in the order shown in the figure 2.116 the required moment:
– bolts of fastening of a head of the block of cylinders 13-20-22-23 (8 N · l),
– bolts of fastening of a cover of a head of cylinders from 1-12, with 14-19 and 21-24 (15 N · м).
Weaken an inhaling of bolts of fastening of a cover of a head of cylinders 13-20-22-23.
Tighten in that order the required moment bolts of fastening of a cover of a head of cylinders 13-20-22-23 (15 N · м).
Fix a magnetic rack on a head of the block of cylinders, using for this purpose a fixing level of adaptation (Mot. 588), having attracted its bolts of fastening of an oil separator and expansion plugs having the following sizes:
– outer diameter is 18 mm,

Fig. 2.117. Installation of a magnetic rack on a head of the block of cylinders: 1 – fixing level; 2 – expansion plugs; 3 – bolts


– diameter of an opening under a bolt of 89 mm, - height is 15 mm (fig. 2.117).

Fig. 2.118. Check of axial movement


Check axial movement which has to be in limits of 0,08-0,178 mm (fig. 2.118).
Uncover a head of the block of cylinders and camshafts.